MOTOR CAPACITY SET and MOTOR POLES SELECT (Parameter No. 66 & 67) |
Used to set the capacity and No. of poles of the motor to be driven. These settings are required for using vector control.
(Parameter No. 66 : Motor capacity setting)
Data setting value | Motor capacity (kW) |
0.2 | 0.2 |
0.4 | 0.4 |
0.7 | 0.75 |
1.5 | 1.5 |
2.2 | 2.2 |
3.7 | 3.7 |
(Parameter No. 67 : Motor poles setting)
Data setting value | No. of motor poles |
2 | 2 poles |
4 | 4 poles |
6 | 6 poles |
Note)
When the data in parameter Nos. 66 and 67 (motor capacity and No. of poles) is changed, the data for parameter Nos. 69 and 70 (voltage compensation constant and slip compensation frequency) will automatically be changed to the recommended motor constants.