Functional Descriptions (By Parameter No.) |
OUTPUT RELAY FUNCTION SELECT(Parameter No.24) |
Data setting value | Function | Conditions for operation status relay to turn ON (terminal No. 7-8: ON, terminal No. 9-8: OFF) |
0 | Run signal | ON when run signal is on or during inverter output |
1 | Arrival signal | On when the commanded frequency is within the set frequency +-2Hz |
2 | Overrload prealarm | On when the output current is 140% of the reated current of higher or when the electronic thermal level is reached. |
3 | Frequency detection signal | On when the commanded frequency exceeds the detected frequency (set in parameter No. 25) |
4 | Reverse run signal | On when the inverter is running in reverse. |
5 | Fault warning signal (Operation 1) | Relay operation is OFF during normal state and ON during fault state. |
6 | Fault warning signal (Operation 2) | Relay operation is ON during normal state and OFF during fault state |